Dynatank · Industrial plant

A compact plant to treat and recycle your industrial water.

Dynatank® brings together the treatment functions your project needs in one compact installation. Its configuration is designed from your effluents, your loads and your discharge or reuse objectives.

Scroll down

The tank

More load.
Less concrete.

A stainless steel ISO tank container, assembled, wired and tested in our workshop. The bioreactor runs at high concentration: for the same load, the biological volume shrinks considerably and the clarifier disappears.

  • 80 kgCOD per day (35 m³ version)
  • 5–100 m³Per day, depending on the configuration
  • 25 to 35 m³Reaction volume per tank

Inside

Two Dynafilter® modules, submerged.

The membrane retains all of the biomass. The membrane discs rotate in the sludge: fouling removal comes from the rotation, with no air scouring dedicated to the membranes.

  • 10–30 g/LBiomass in the reactor
  • 30–60 nmFiltration fineness
  • 0.5–1kWh per m³ treated

Anatomy of a module

Membrane carriages on a single shaft.

Each module carries several carriages of membrane discs. Is your flow increasing? Carriages are added on the existing shaft; the tank stays the same.

Needs covered

Your factory grows. Your treatment keeps up.

New installation, upgrade of an existing treatment, space or load constraints: the four situations that bring us to an industrial site.

Production is increasing

New line, new product, higher output: the existing plant is saturated and there is no land to expand it.

The discharge agreement is tightening

Repeated exceedances, pollution load surcharged by the local authority, discharge authorization called into question.

The prefectural order demands more

New limit values in the operating permit issued by the French State, formal notice, permit renewal: you need results fast.

Water becomes a resource

Drought orders, water prices, CSR goals: reuse treated water for washing, cooling or utilities.

Process

Your production varies. Your discharge quality doesn't.

In industry, the effluent mirrors production: it rises with output, drops at weekends, changes with recipes and takes in cleaning water at the end of each shift. Dynatank is designed to absorb these swings.

The functions shown are those of the standard configuration; pretreatment and any additional treatment are defined according to your effluent and your objective.

  1. MBBR — attached biomass

    The biofilm attached to the carriers handles load shocks and clean-in-place cycles better than suspended sludge.

  2. Anoxic

    Denitrification and aeration savings.

  3. High-load aerobic

    Concentrated biomass, fine-bubble aeration: a much smaller biological volume for the same load.

  4. Dynafilter® ultrafiltration

    Submerged filtration kept clean by the rotation of the discs: ultrafiltered permeate, the basis of a reuse strategy. The Dynafilter technology

Sizing

Sizing basis for one tank.

Flow alone is not enough to define an industrial plant. The study takes into account the nature and load of the effluents, their variability, pretreatment and the target performance.

Nominal capacity

80 kg COD / day 35 m³ version — each project is sized on your hydraulic and mass balance

Flows

Average 1,800 L/h — peak 3,000 L/h 5 to 100 m³/day depending on the configuration

Incoming effluent

COD 400 to 2,500 · BOD 200 to 1,200 · TSS 150 to 1,500 mg/L Typical ranges; more concentrated effluents on request

Temperature

5 to 40 °C

Required pretreatment

2 mm screening in all three dimensions

Effluents to be validated

Solvents, hydrocarbons, pH outside 5–9, ecotoxic reagents, brines

Container

Stainless steel ISO tank container (swap body) — 25, 30 or 35 m³

Biomass concentration

10 to 30 g/L

Membranes

Dynamic ultrafiltration, 30 and 60 nm

Aeration

Rotary lobe blower, fine-bubble diffusers

Instrumentation

Flow, redox, dissolved oxygen, TSS, nitrogen, pressure, conductivity Measured continuously and logged: self-monitoring data ready to submit

Power consumption

0.5 to 1 kWh per m³ treated

Scalability

Add on. Don't rebuild.

A conventional plant is sized for the production expected in ten years, and paid for from day one. Dynatank is sized for today and grows with standard components.

Diagram of Dynatank extensions: an additional filtration module in the tank, two membrane carriages on the existing module, two or three Dynatanks coupled in parallel on a common feed.
Illustration: extensions planned from the design stage, without tearing down what works.

+ Filtration carriages

Your flow increases: carriages of membrane discs are mounted on the shaft of the existing modules. Filtration area increases; the tank stays the same.

+ Submerged module

You want more flow and redundancy: an additional module is submerged in the tank, and one module can be serviced while the other keeps filtering.

+ Parallel tank

Your pollution load increases: an additional ISO tank is installed in parallel, on a common feed. Biological volume, aeration and filtration add up.

Integration

Plug-in. Treat. Reuse.

Dynatank arrives on site in an ISO tank container, with the process assembled, wired and tested in our workshop. Four connections and a three-phase socket: site work comes down to the slab, the connections and commissioning.

  • DN65Raw effluent
  • DN32Permeate
  • DN50Sludge
  • DN100Drain
  • 16 A 3-phasePower

Provided by AKELION

  • Process core: ISO tank, biology and submerged filtration
  • Instrumentation, connections, accessories and interfaces
  • PLC, supervision and process utilities
  • Technical file and documentation
  • Commissioning and operator training

Provided by the client or the integrator

  • Civil works: slab, footings, ground beams
  • Upstream (collection) and downstream (discharge, reuse) networks
  • Removal of sludge and screenings
  • Site power supply and upstream protection
  • Local compliance: planning permission, ICPE (French classified-facility regime) if applicable

The scope of supply and the responsibilities are specified for each project. Optional peripheral modules: screen, buffer tank, sludge press, chlorination, distribution.

Test before you invest

What you measure is what you buy.

No two industrial effluents are alike. Rather than extrapolating from generic values, AKELION provides two pilot units to measure, on your site and with your effluent, what really drives the project.

  • Dynafilter pilot Qualify filtration on your sludge, in your biological basin
  • Dynatank pilot Validate the complete process at full scale
  • Duration A few weeks, without shutting down your plant
  • At the end Campaign report, binding sizing, firm offer

COD removal

Typical value observed> 96%

Turbidity removal

Typical value observed~ 99%

NH₄ removal

Typical value observed> 99%

Typical values observed during AKELION validation campaigns, with biological treatment combined with dynamic filtration. The pilot on your effluent sets yours.

Food and beverageDistilleriesProcess industryLeachate

Operation

Less energy. Less sludge. Less water drawn.

Robust and durable

Stainless steel tank, submersible mechanics, protections suited to aggressive effluents. Plannable maintenance. 5-year equipment warranty, subject to the general terms of sale.

Up and running quickly

Delivered tested from our workshop, with delivery possible in less than 3 months. No structure to build.

Remotely monitored

PLC, prioritized alarms, history and remote supervision. Neural Water Management® advanced control can be considered as an addition.

Less sludge

The high sludge age reduces excess sludge production; withdrawal is done at high concentration: less volume to store and fewer trucks.

Frequently asked questions

Preparing your preliminary study.

New plant or addition to the existing one?

Both situations can be studied. The choice depends on the existing treatment, the effluents and the objectives, with an integration scope defined for the project.

What data should I send?

Average and peak flows and their variations, available analyses (COD, BOD, TSS, TKN, pH), temperature and fat content, production calendar, current discharge method and requirements. This information helps prepare the sizing and any useful trials.

What equipment is included?

The scope of supply is specified in the offer: treatment functions, ancillary equipment, automation and interfaces. Connections and site work are identified separately when necessary.

How should operation be organized?

Operating and maintenance conditions are set with the integrator partner suited to the site's activity and location, according to the agreed services.

Contact

A first 30-minute conversation.

That's enough to know whether Dynatank meets your needs. Describe your business, your effluents and your main constraint.

Workshop
10 rue du Sauvignon
34800 Clermont-l'Hérault, France
Preferred contact

AKELION uses this information to answer your request and follow up on your project. Fields marked with an asterisk are required for us to reply. For recipients, retention periods and your rights, see our privacy policy.