Submerged dynamic membrane filtration

Upgrade your existing plant with Dynafilter®.

Dynafilter puts the membranes in motion right inside the basin. This submerged dynamic filtration lets you upgrade existing structures and prepare a water reuse project, depending on the characteristics of the effluent and the installation.

Scroll down

The problem

Fouling
costs energy.

On a conventional membrane bioreactor, preventing fouling requires constant air scouring. That air is electricity—the largest energy cost of membrane filtration.

The answer

Here, the membranes move.

In dynamic filtration, the motion comes from the rotor itself. Fouling removal no longer needs air scouring, head loss stays minimal, and filtration can even run by gravity, without pumping.

Anatomy

One module,
submerged as is.

The module goes straight into the basins already in place. Cleaning is automatic and in situ: the membranes never leave the water.

Loading the model

Principle

How Dynafilter® works.

Conventional technologies move the fluid. Dynafilter moves the membrane.

In conventional crossflow filtration, the shear that keeps deposits from building up is created by pumping the effluent at high speed along the membrane. The entire mass of fluid has to be moved, all the time.

Dynafilter reverses the equation: the membrane discs, submerged in the basin, rotate on their axis. Shear comes from the motion of the membrane—around a hundred kilos of discs instead of roughly a ton of circulating fluid.

The resulting shear is higher, and the energy used is far lower. That is what makes fouling removal possible without constant air scouring, and gravity filtration achievable.

Fouling removal by rotation reduces the need for air for this function; any aeration required by the biological treatment is a separate matter, sized with the process.

  • Water to be treated
  • Retained solids, released by the rotation
  • Filtered water, toward the hollow shaft
A membrane disc seen from the front. Water passes through the membrane and reaches the hollow shaft; shear is produced by the rotation of the discs, not by the circulation of the effluent. 70 to 80% energy reduction observed compared with traditional crossflow filtration.

Integration

In the basins you already have.

The study specifies the pretreatment, connections, service equipment and access required. It also sets the conditions for integration into the structure and for keeping operations running during the work.

The module fits anoxic and aerobic reactors, anaerobic digesters and MBBR reactors, in new builds as well as retrofits, in basins 1 to 12 m deep.

  • The Dynafilter® module

    Submerged in the biological basin. Its length extends in 1-meter steps, from 2 to 7 meters, and modules can be stacked up to three units high.

  • The Utility Dock

    The service unit that houses the PLC, permeate suction, backwash and cleaning utilities.

  • Pretreatment

    It protects the equipment: effluent prefiltered to less than 2 mm. A protective screen is available for emergency applications and MBBR reactors.

  • Remote control

    Automated unit, monitored and controlled remotely via GSM modem and a web platform. Neural Water Management® advanced control can be considered as an addition.

Specifications

The figures, plainly stated.

Ranges covered by the Dynafilter® line, from the single module to the six-carriage module. Exact sizing depends on the effluent and the selected configuration.

Standard module

6,500 × 550 × 650 mm — 300 kg in operation Length adjustable from 2 to 7 m, stackable on 3 levels

Filtration area

10 to 70 m² per module 40 m² for the standard module

Membrane cut-off

30 nm · 50 nm · 200 nm PES, PVDF or ceramic depending on the application

Permeate flux

25 to 35 L/h·m², occasional peaks up to 45 10 to 35 L/h·m² measured on industrial effluent, Briane Environnement trial

Transmembrane pressure

400 to 2,000 mbar depending on the series 200 to 670 mbar recorded in operation during the pilot trial

Rotation speed

180 to 400 rpm Adjusted automatically to the fouling rate

Motor

Submerged, 3.2 kW IE5 with variable frequency drive Leak detection as an option

Sludge concentration

10 to 30 g/L MLSS Depending on the effluent and the biological configuration

Effluent

Viscosity 1 to 300 mPa·s — prefiltration < 2 mm Temperature 5 to 50 °C · pH 3 to 10 in production, 2 to 12 during cleaning

Immersion depth

1 to 12 m For basins from 2 m in diameter

Materials

Stainless steel 1.4404 · PPS + GF · EPDM Three SiC mechanical seals between sludge and permeate

Effluent types

Municipal · Agro-industrial · Winery · Leachate High-strength, highly variable effluents

Measured performance

Pilot trial
before investment.

Four weeks of continuous operation on a real, highly variable industrial effluent. Not a lab: a site in production.

  • Site Briane Environnement (Tarn, France) — agro-industrial effluent
  • Period January – February 2026, 4 weeks
  • Configuration Dynafilter S module, 50 nm PVDF membranes
  • Filtered flow 12 m³/day
  • Membrane flux 10 to 35 L/h·m²
  • TMP 200 to 670 mbar
  • Backflush 1 cycle / 90 minutes
  • Backwash Only 1 over the entire period

Before — incoming effluent

COD1,200 mg/L
TurbidityHigh

After — permeate

Residual COD< 60 mg/L
Clarity< 1 NTU
COD removal> 93%

Operation

Consumption0.65 kWh/m³
Availability98.6%

Data recorded on the AKELION demonstrator installed at Briane Environnement, a waste treatment and recovery company in the Tarn, France. Availability excluding the February 17 incident. The measured removal results from biological treatment combined with filtration; performance depends on the nature of the effluent and on operating conditions.

Practical benefits

What Dynafilter® changes for your plant.

Up to 5×

More capacity, same basin

Biological sludge concentrated up to 30 g/L MLSS. The existing volume treats more, without building a new one.

Up to −70%

Power consumption

Gravity filtration possible, minimal head loss, no air scouring needed to keep the membranes clean.

Compared with other membrane bioreactor (MBR) technologies, for the filtration function.

Class A

Water ready for reuse

A physical barrier that retains suspended solids. Compatible with treatment trains targeting Class A under French water reuse rules, depending on the intended use and the conditions applicable to the site.

0 basins to build

Built into what you have

The module goes into the basins in place: no dedicated basin, no extra land, less construction work.

5-year warranty

Simpler maintenance

Automatic in-situ cleaning without removing the membranes. Every part, including each disc, can be replaced individually. Warranty subject to the general terms of sale.

Made in France

Designed and built in France, with French sourcing preferred

Industrial quality, units tested at the factory before shipping, and maintenance partners organized by region.

As a mission-driven company (société à mission), our articles of association commit us to favoring manufacturing in France or Europe, even at a reasonable extra cost.

Implementation

Plug & play, in the basin you already have.

Technical discussion

An AKELION engineer reviews your effluent, the volume to treat and your main constraint.

Study and trial

Module layout, additional equipment and the organization of the work are defined, after a pilot trial if needed.

Immersion and commissioning

The module is installed in the existing basins. Keeping operations running during the work is planned from the study stage.

Operation

Automatic in-situ cleaning, membranes never taken out of the water, 5-year warranty (subject to the general terms of sale) and a trained integrator partner.

Demonstrator

Come and see it run.

The full-scale Dynafilter® demonstrator is already installed and can be visited at several industrial sites in the region. Host it on your site to see its full potential for yourself.

Frequently asked questions

Before equipping your plant.

Can an existing plant be equipped?

It depends on the basin, the effluents, the loads and the access conditions. The study determines the module layout, the additional equipment and how the work is organized.

Is pretreatment needed?

Pretreatment protects the equipment and limits the entry of unwanted material. Its type and fineness are defined from the effluent and the selected configuration.

Does Dynafilter replace the whole treatment process?

Dynafilter provides membrane filtration. Biological treatment and the other steps required depend on the pollution to be treated and the project objectives.

Who maintains the system?

Integrator partners handle maintenance and operation, depending on the market and the region. Services and responsibilities are defined for each installation.

Contact

A question about Dynafilter®?

Describe your installation and your needs: an AKELION engineer will review your request and get back to you for a technical discussion.

Workshop
10 rue du Sauvignon
34800 Clermont-l'Hérault, France
Preferred contact

AKELION uses this information to answer your request and follow up on your project. Fields marked with an asterisk are required for us to reply. For recipients, retention periods and your rights, see our privacy policy.